Passive and A1-rated rural ICF homes

Building a passive-standard A1-rated ICF home in Ireland costs €2,550 to €3,250/m² turnkey incl. 13.5% VAT, roughly €200 to €250/m² over a baseline NZEB spec due to deeper graphite-enhanced EPS forms, triple glazing, passive raft detailing and balanced MVHR ventilation.

Reaching 0.11 W/m²K wall U-values, sub-0.6 ACH50 blower-door scores and near-zero winter heating demand without awkward wall add-ons.

Free, no obligation. One local builder prices it, not five.

  • €2,550–€3,250/m²turnkey passive A1 incl. 13.5% VAT
  • 0.11 W/m²Kdeep graphite EPS wall U-value
  • < 0.6 ACH50Passive House airtightness ceiling
  • A1 BERtypical completed Irish energy rating
Contemporary two-storey low-energy house with dark window frames, rendered walls, timber cladding and green lawn

Why ICF reaches Passive House metrics so predictably

Standard Irish Building Regulations (TGD Part L) set a backstop external wall U-value of 0.18 W/m²K and maximum air permeability of 5.0 m³/(h·m²). Certified Passive House standards tighten that air-leakage limit roughly eightfold to 0.6 ACH50 and demand near-zero linear thermal bridging (psi-values). Because an ICF wall wraps a solid monolithic concrete core inside unbroken outer graphite-enhanced EPS from raft bottom to roof eaves, the wall structure itself becomes the primary airtightness layer.

Standard NZEB ICF (A2/A1)

Outer EPS thickness
100 to 150 mm EPS/Neopor
Wall U-value
0.13 to 0.15 W/m²K
Blower-door target
0.8 to 1.5 ACH50
Glazing & ventilation
Triple glazing + DCV or MVHR

Passive-spec ICF (A1)

Outer EPS thickness
200 to 250 mm graphite EPS
Wall U-value
0.10 to 0.12 W/m²K
Blower-door target
At or below 0.6 ACH50
Glazing & ventilation
Certified triple Uw <=0.8 + MVHR

Price my ICF home

Four taps show your Irish ICF build figure before we ask for a phone number. One local builder rings you, not five.

Example: A passive A1-rated ICF home, 150 to 200 m², full turnkey (planning granted) comes to €446,000 to €569,000 (€2,550 to €3,250/m² incl. 13.5% VAT).

Step 1 of 5

Which ICF home layout fits your site?

Pick the closest match. Your builder checks floor plans on site.

How this ICF build range is calculated

Figures multiply going Irish ICF shell-and-core (€1,250 to €1,820/m²) or full turnkey (€2,300 to €3,250/m²) build rates, inclusive of 13.5% construction VAT, by the midpoint of your chosen floor area band. Dublin sites carry a 6% site-access weighting and Kildare, Meath and Wicklow carry a 3% weighting. Site acquisition, percolation/septic tanks, ESB/water connection fees, kitchen PC upgrades and architect or engineer fees sit outside the base build rate. Only a builder reviewing your planning drawings and soil test gives a firm tender figure.

Five thermal-bridge traps passive ICF detailing removes

  • Wall-to-floor perimeter junction. Sitting ICF starter courses directly onto an insulated EPS ring-beam raft eliminates the cold concrete strip footing bridge.
  • Window and sliding-door reveals. Positioning triple-glazed frames directly inside the outer EPS insulation zone and taping frames cleanly prevents cold perimeter condensation.
  • Thermally broken window cills. Heavy cast-concrete cills conduct outdoor chill straight inside; passive ICF homes use insulated powder-coated aluminium or composite cills.
  • First-floor slab perimeter. Recessed slab pockets keep the continuous outer EPS skin running uninterrupted past hollowcore or timber floors.
  • Airtight service penetrations. Grouping ESB, water, heat-pump and MVHR ducts through sleeved airtight grommets protects your blower-door score before plastering.

Common questions before you pour

How much extra does a Passive House ICF spec cost in Ireland?

Expect €200 to €250/m² above a standard NZEB ICF build (€2,550 to €3,250/m² turnkey incl. VAT), driven mainly by thicker outer graphite EPS, higher-spec triple glazing, MVHR ductwork and certified passive-raft detailing.

Do passive ICF homes still need an air-to-water heat pump?

Most Irish A1 passive-standard homes pair a compact 5 to 7 kW air-to-water heat pump with low-temperature underfloor heating or heated towel rails and domestic hot water, keeping annual heating bills very low.

Does a passive ICF house overheat in summer?

High-thermal-mass concrete cores absorb daytime heat swings far better than lightweight frames, provided large south- and west-facing glazed elevations include roof overhangs or external shading.

Is formal Passive House Institute certification mandatory for an A1 BER?

No. Many Irish self-builders build to passive wall U-values (0.11 W/m²K) and <0.6 ACH50 airtightness using PHPP thermal modelling without paying for formal overseas certification.

All ICF home pages and technical references

Contemporary two-storey low-energy house with dark window frames, rendered walls, timber cladding and green lawn

See your ICF self-build cost before anyone rings

Choose the house layout, approximate floor area and shell or turnkey scope. When you want a builder's figure, your outline goes to a single ICF home builder in your county.